Home Discussions Questions & Answers Which time limit setting is used if multiple are defined?

Which time limit setting is used if multiple are defined?

Avatar photoCustomer July 13, 2022 at 4:02 am

We have a maximum run time set at the report definition level, but users can also input a time limit in the Options window. Which value takes precedence?

Viewing 6 reply threads
  • Author
    Replies
    • Support July 13, 2022 at 9:53 pm  

      The time limit can be set at multiple levels, and they follow a strict order of precedence. The highest priority is the Run window options time limit.

    • Avatar photoCustomer July 14, 2022 at 2:26 pm  

      What is the full order of precedence, descending from the highest priority?

    • Support July 14, 2022 at 9:42 pm  

      The order is: 1. Run window options time limit, 2. Profile option on user level, 3. Time limit on report level, 4. Profile option on responsibility level, and finally, 5. Profile option on site level.

    • Avatar photoCustomer July 16, 2022 at 6:22 am  

      What is the unit of measure for this time limit?

    • Support July 16, 2022 at 7:34 pm  

      The time limit is indicated in seconds. However, there is a profile option, ‘Blitz Report Time Limit in minutes’, for setting a default maximum execution time limit in minutes.

    • Avatar photoCustomer July 17, 2022 at 10:55 pm  

      And how is this time limit enforced?

    • Support July 18, 2022 at 4:42 am  

      The maximum run time limit is enforced by the ‘Blitz Report Monitor’ concurrent program. This automatically cancels reports exceeding the limit to avoid excessive server load.

Viewing 6 reply threads
  • You must be logged in to reply to this post.